Herunterladen Inhalt Inhalt Diese Seite drucken

Custom Code Setting; Switching The Upper Limit Of Cooling Temperature; Function Setting - AirStage ASYA07GACH Installationsanleitung

Innengerät (wandmontierter typ: eev intern). nur für autorisiertes fachpersonal
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
3 Remote controller address
i)
3-wire type
Rotary switch (RC AD SW)...Factory setting "0"
When connecting multiple indoor units to 1 standard wired remote controller, set
the address at RC AD SW in sequence from 0.
Setting
Setting range
Remote controller
0 to 15
address
Example
If 4 indoor units are connected.
Indoor unit
Indoor unit
RC AD SW
RC AD SW
0
1
Remote
controller
RC AD SW
0
1
Address
0
1
RC AD SW
8
9
Address
8
9
ii) 2-wire type
Rotary switch (RC AD SW)...Factory setting "0"
Since the remote controller address settings are automatically confi gured, you do
not need to confi gure them.
If confi guring manually, it is necessary to confi gure both the indoor unit and the
remote controller. For details, please refer to the remote controller manual.

6.2. Custom code setting

Selecting the custom code prevents the indoor unit mix-up.
(Up to 4 codes can be set.)
Perform the setting for both the indoor unit and the remote controller.
Confusion
Indoor
unit
Remote
controller
Custom code setting for indoor unit
Set the DIP switch SET 3 SW1, SW2 referring to the Table B.
DIP switch (SET 3)
OFF
ON
SW1
SW2
SET 3
SW3
SW4
Table B
A (Factory setting)
DIP switch
OFF
SET 3 SW1
DIP switch
OFF
SET 3 SW2
6.3. Switching the upper limit of cooling
temperature
This setting can be raised the upper limit of the cooling temperature setting range.
This setting can be used when connecting to the following controllers.
• Wired remote controller (2-wire type)
• Central remote controller
• Touch panel controller
• System controller
• Service tool
• Web monitoring tool
En-9
9373370130-01_IM.indb Sec1:9
9373370130-01_IM.indb Sec1:9
Type of switch
Setting
example
0
RC-AD
Indoor unit
Indoor unit
RC AD SW
RC AD SW
2
3
2
3
4
5
6
2
3
4
5
6
A
B
C
D
E
10
11
12
13
14
Code change
A
B
C
A
B
C
Controller PCB
Custom code
B
C
ON
OFF
OFF
ON
DIP switch setting
Set the DIP switch SET 4 SW3 referring to the Table C.
DIP switch (SET 4)
OFF
ON
SW1
SW2
SW3
SW4
Table C
DIP switch SET 4 SW3
OFF (Factory setting)
ON
NOTE:
Please do not make a standard setup and an extension setup intermingled in remote
controller group.

6.4. Function Setting

7
7
• FUNCTION SETTING can be performed with the wired or wireless remote controller.
F
(The remote controller is optional equipment)
• Refer to the wired or wireless remote controller manual for detailed setting information.
15
(Set IU AD, REF AD SW to 0)
• Refer to "6.1. Setting the address." for indoor unit address and refrigerant circuit address
settings.
• Turn the power of the indoor unit ON before starting the setting.
* Turning on the power to the indoor units initializes EEV, so make sure the piping air
tight test and vacuuming have been conducted before turning on the power.
* Also check again to make sure no wiring mistakes were made before turning on the
power.
Function details
Function
Function
Setting number
number
00
Filter
indicator
11
01
interval
D
02
00
Filter
01
indicator
13
action
D
02
00
Cool air
temperature
30
01
trigger
02
00
Heat air
01
temperature
31
02
trigger
03
00
Auto restart
40
01
00
Cool Air
43
Prevention
01
00
D
ON
01
External
46
control
ON
02
00
Error report
47
target
01
Fan setting
00
when cooling
49
thermostat
OFF
01
Controller PCB
SET 4
Cooling temperature setting range
Standard (18 to 30 °C)
Extension (18 to 32 °C)
Default
Details
Adjust the fi lter cleaning interval noti-
Default
fi cation. If the notifi cation is too early,
Longer
change to setting 01. If the notifi cation
is too late, change to setting 02.
Shorter
Enable
Enable or disable the fi lter indica-
Disable
tor. Setting 02 is for use with a
Display only on
central remote controller.
central remote
controller
Default
Adjust the cool air trigger temperature.
To lower the trigger temperature,
Adjust (1)
use setting 01. To raise the trigger
temperature, use setting 02.
Adjust (2)
Default
Adjust the heat air trigger temperature.
To lower the trigger temperature by 6
Adjust (1)
degrees C, use setting 01. To lower the
trigger temperature by 4 degrees C, use
Adjust (2)
setting 02. To raise the trigger tempera-
ture, use setting 03.
Adjust (3)
Enable
Enable or disable automatic sys-
tem restart after a power outage.
Disable
Super low
Restrain the cold airfl ow with mak-
ing the airfl ow lower when starting
Follow the
heating operation. To correspond
setting on the
to the ventilation, set to 01.
remote controller
Allow an external controller to start
Start/Stop
or stop the system, or to perform an
emergency stop.
Emergency
* If an emergency stop is performed
stop
from an external controller, all refriger-
ant systems will be disabled.
* If forced stop is set, indoor unit stops
Forced stop
by the input to the external input
terminals, and Start/Stop by a remote
controller is restricted.
All
Change the target for reporting errors.
Errors can either be reported in all
Display only on
locations, or only on the wired remote.
central remote
controller
Follow the setting
When set to 01, the fan stops when
on the remote
the thermostat is OFF in cooling
controller
operation. Connection of the wired
remote controller (2-wire type or 3-wire
type) and switching its thermistor are
Stop
necessary.
7/12/2012 2:29:46 PM
7/12/2012 2:29:46 PM

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis