Problem and alarm code
The appliance does not fill
with water.
The display shows
The appliance does not
drain the water.
The display shows
The anti-flood device is on.
The display shows
The appliance stops and
starts more times during op‐
eration.
The program lasts too long.
The remaining time in the
display increases and skips
nearly to the end of program
time.
Small leak from the appli‐
ance door.
The appliance door is diffi‐
cult to close.
Rattling/knocking sounds
from inside the appliance.
The appliance trips the cir‐
cuit-beaker.
Possible cause and solution
Make sure that the water tap is open.
Make sure that the pressure of the water supply is not too
low. For this information, contact your local water authori‐
.
ty.
Make sure that the water tap is not clogged.
Make sure that the filter in the inlet hose is not clogged.
Make sure that the inlet hose has no kinks or bends.
Make sure that the sink spigot is not clogged.
Make sure that the filter in the outlet hose is not clogged.
Make sure that the interior filter system is not clogged.
.
Make sure that the drain hose has no kinks or bends.
Close the water tap and contact an Authorised Service
Centre.
.
It is normal. It provides optimal cleaning results and ener‐
gy savings.
Select the Time Saver option to shorten the program time.
If the delayed start option is set, cancel the delay setting
or wait for the end of the countdown.
This is not a defect. The appliance is working correctly.
The appliance is not levelled. Loosen or tighten the adjust‐
able feet (if applicable).
The appliance door is not centred on the tub. Adjust the
rear foot (if applicable).
The appliance is not levelled. Loosen or tighten the adjust‐
able feet (if applicable).
Parts of the tableware are protruding from the baskets.
The tableware is not properly arranged in the baskets. Re‐
fer to basket loading leaflet.
Make sure that the spray arms can rotate freely.
The amperage is insufficient to supply simultaneously all
the appliances in use. Check the socket amperage and
the capacity of the meter or turn off one of the appliances
in use.
Internal electrical fault of the appliance. Contact an Au‐
thorised Service Centre.