104
Above a 90 cm ATAG oven or an oven of another make without casing
cooling.
Fit a heat-resistant (85 °C) plate to screen off the
hob. Ensure that the space between the hob and
the protective plate is ventilated. This space must
not be connected with the space above the oven.
The space between the underside of the hob and
the top of the protective plate must be at least
25 mm.
Sealing tape
Stick the sealing tape on the underside of the
edge.
Don't stick the sealing tape around the corner;
rather cut four pieces to fit effectively in the
corners.
Turn the hob over and allow the appliance to sink
into the opening.
installation guide
105
Only for CKT755
Secure the hob using the fasteners supplied.
In the case of worktops thinner than 40 mm a filler block has to be used between
the fasteners and the worktop. The screws must be screwed into the pressed holes.
Connecting up and checking hob
Make the electrical connection by inserting the plug in the socket or set the
switch of the power supply cable (in the case of a fixed connection) to 1.
Test to check the hob is operational.