Herunterladen Inhalt Inhalt Diese Seite drucken

Changing The Soldering Tip; Temperature Calibration - ersa i-CON NANO MK2 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für i-CON NANO MK2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3

Changing the soldering tip

Various soldering tips can be
used with the i-CON NANO sol-
dering station. In this way, the
soldering station can be adapted
to various areas of operation.
More soldering tips are available
from the Ersa dealer. Download-
able overview of i-TOOL tips:
142.ersa.com

Temperature calibration

If the set temperature and
the actual temperature of the
soldering tip do not concur, then
the temperature can be cali-
brated in order to resume work
at exact soldering temperatures.
Default value: 0
Value range:
− 70 to +50 °C
−126 to +90 °F
13 Switch off soldering station
and allow soldering tip to cool
to approx. 40 °C / 104 °F.
14 Screw soldering tip onto the
knurled section of the solder-
ing iron.
15 Remove soldering tip from
soldering iron.
16 Place desired soldering tip
onto soldering iron.
17 Fit soldering tip with knurled
section onto soldering iron
and check for correct fit.
18 Switch on soldering station.
ATTENTION! Soldering tip is
hot! Risk of burning yourself!
19 Select reference value for
calibration at the soldering
station.
20 Determining actual tempera-
ture using a digital tempera-
ture-measuring instrument.
21 Calculating deviation be-
tween reference value and
actual value.
22 Press both keys briefly to call
up the calibration menu.
23 Setting temperature using
the keys in accordance with
the deviation.
24 Wait five seconds to save the
value.
English
9
|

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis