Herunterladen Inhalt Inhalt Diese Seite drucken

Limit Value Formation And Alarms - Emerson CSI 6500 Machinery Health Monitor A6110 Schnellstartanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product Information / Produktinformation A6110
Shaft Vibration Monitor

1.6.3 Limit value formation and alarms

Two alarm channels, each with an alarm output ALERT and DANGER, and separate limit value
adjustment. Alarming if the characteristic value exceeds the limit value parameters. (actual
value > limit value)
Setting the limit value
Through setting parameters, depending on the configuration for measurement operation,
characteristic value formation, range etc.
Setting condition
Setting range
Resolution and reproducibility
Hysteresis
Alarm delay
Can be configured to 0 (off), 1,2,3,4,5 sec.; effective on the alarm outputs.
Alarm blocking
Blocking
No blocking
* In the configuration it is specified whether the alarm outputs will be blocked through channel
monitoring.
Alarm visualization
Through one red LEDs each for channel 1 and channel 2
No limit value exceeded or alarm
blocked
ALERT, no DANGER
DANGER
Limit value ALERT < limit value DANGER
0 ... 100
of the measuring range parameters
%
1 % based on the measuring range end value
Configurable, 0 ... 20 % based on the measuring range
end value
The hysteresis is only effective with decreasing actual
value
If (C&P active = yes)
(Voltage or watchdog not OK)
(Ext. disable = disable)
(Channel status = error and limit value
suppression on*)
(Channel status = release delayed)
Channel monitoring effect = yes
If the above condition is not satisfied
LED off
LED flashes at 2 Hz (pulse/pause 1:1)
LED on continuously
Page 18
OR
OR
OR
OR
AND

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis