Herunterladen Inhalt Inhalt Diese Seite drucken

Emerson CSI 6500 Machinery Health Monitor A6110 Schnellstartanleitung Seite 12

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product Information / Produktinformation A6110
Shaft Vibration Monitor
3. Use a cross head screwdriver to remove the four cross−headed screws, identified with the
arrows, in the following figure.
4. Carefully pull the controller board off the main board without tilting it. The position of the J2
jumpers on the main bard is identified with a white frame in the following figure.
5. To switch the raw sensor signal to terminals z14 and z16 place the jumpers as shown in b).
If the jumpers are set as shown in a) then the dynamic portion of the sensor signal is applied
on terminals z14 and z16.
SENS1
z14:
z16:
SENS2
AC1
SENS1
z14:
J2
z16:
AC2
SENS2
a)
Page 12
AC1
J2
AC2
b)