6. Place the controller board back on the main board and secure it with the four screws. Now,
the raw sensor signal is on the connection strip.
Installation
1. Check the slot wiring prior to installing the monitor.
2. Push the A6110 monitor into the prepared slot and press it with light pressure into the plug
connector.
3. Hand tighten the two anchoring screws on the front panel to secure the monitor.
Any other information, e. g. shielding and grounding, configuration of the monitor, etc., can be
found in the direction for use "Shaft Vibration Monitor A6110", order number: 6110−90001.
1.6

Technical Data

Only information with tolerances and limit values are considered as binding data. Data without
tolerances or error limits are provided as information only. We reserve the right to make technical
changes − particularly to the software.
All of the following information applies uniformly for channel 1 and channel 2, if not otherwise
specified.

1.6.1 Signal conditioning

Two separate signal inputs for channel 1 and channel 2 with uncoupled signal conditioning.
Measured value inputs
Differential voltage amplification inputs, non−reactive, open−circuit and short−circuit proof.
Channel 1
Channel 2
Input nominal range
Limit range
Input resistance
z8: SENS1H (+); z10: SENS1L (− Signal)
d8: SENS2H (+); d10: SENS2L (− Signal)
−1,0 ... −22.16 V
0 ... −30 V DC
> 100 kΩ