SYSTEM FOR A CLOSED TANKINSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE WITH HOT SANITARY WATER PRO-
KIT 6
DUCTION USING
Elec-
tricity
Mains
Kit 6 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the
product to be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted
Electrical Connections
Power Supply
230 Vac
Circulator
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY
Regulator
(included in the kit)
Fuse
Display
20 - 80° C
Valve Setting
Circulator enabled
Overheating alarm
3-way valve
20 - 80° C
Circulator Setting
Flow Switch
normally closed contact
1
2
3
5
6
7
8
9
10
11
12
13
15
16
A
B
C
D
E
F
G
OFF
OFF
ON
ON
Enable
Disable
Acoustic
Alarm
Sensor (insert in the
appropriate well)
- 39
-
Hot Sanitary Water
Cold Water
Water Mains Supply
3-way Solenoid Valve
Normally Open
Normally Closed
Flow Switch
Filling unit
Automatic Relief Valve
Manual Relief Valve
Manometer
System Flow
Pump (circulator)
Radiators
Electronic Regulator
System Return
Drain
Plate Exchanger
Temperature Sensor
Ball Valve
Closed Expansion Tank
Check Valve
Pressurised Safety Valve
VST
Thermal Relief Valve
1" Ball Valve
Circulator (219660)
¾" Male 3-way Solenoid Valve (283690)
Fittings
20-plate Heat Exchanger for hot sanitary water
Temperature Relief Valve Nozzle
Closed Expansion Tank (283680)
Flow Switch (220830)
½" Thermometer Well + Sensor (175960)
Electronic Regulator (220780)
Manometer (269590)
Fireplace Return
System Return
Fireplace Return
Cold Sanitary Water
Pressure Relief Valve
Hot Sanitary Water
Temperature Relief Valve
SELECTOR FUNCTIONS
Selector: OFF
Everything is switched off
Selector: MAN
Driven Circulator
Valve is set
Selector: AUTO
Circulator is set
Valve is set
Alarm selection
No acoustic signal in the
OFF position
KIT 6
code 280600