Herunterladen Inhalt Inhalt Diese Seite drucken

EdilKamin H2 OCEANO 15 Installations-, Betriebs- Und Wartungsanleitung Seite 38

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
SYSTEM FOR A CLOSED TANKINSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE - ONLY HEATING USING
Elec-
tricity
Mains
Kit 5 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the
product to be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted
Electrical Connections
Power Supply
230 Vac
Circulator
3-way
valve
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY
Regulator
(included in the kit)
Fuse
Display
20 - 80° C
Valve Setting
Circulator enabled
Overheating alarm
3-way valve
20 - 80° C
Circulator Setting
1 1" Ball Valve
6 ¾" Male 3-way Solenoid Valve (283690)
7 Fittings
9 Temperature Relief Valve Nozzle
10 Closed Expansion Tank (283680)
12 ½" Thermometer Well + Sensor (175960)
13 Electronic Regulator (220780)
16 Manometer (269590)
A Fireplace Flow
B System return
C Fireplace Return
E Pressure Relief Valve
G Temperature Relief Valve
OFF
OFF
ON
ON
Enable
Disable
Acoustic
Alarm
Sensor (insert in the
appropriate well)
- 38
-
KIT 5
Water Mains Supply
3-way Solenoid Valve
Normally Open
Normally Closed
Filling unit
Automatic Relief Valve
Manual Relief Valve
Manometer
System Flow
Pump (circulator)
Radiators
Electronic Regulator
System Return
Drain
Temperature Sensor
Ball Valve
Closed Expansion Tank
Check Valve
Pressurised Safety Valve
VST
Thermal Relief Valve
SELECTOR FUNCTIONS
Selector: OFF
Everything is switched off
Selector: MAN
Driven Circulator
Valve is set
Selector: AUTO
Circulator is set
Valve is set
Alarm selection
No acoustic signal in the
OFF position
KIT 5
code 280590

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

H2 oceano 23H2 oceano 28

Inhaltsverzeichnis