Ash on the
Flue pipes are not air-
floor around
tight
the stove
Broken, worn or dam-
aged door seal
Stove in con-
The room temperature
stant mode,
desired by the user has
the display
been reached
shows: "Eco"
Display shows
No error. The stove re-
"SERV"
quires a service every 900
hours of operation. The
stove will simply continue
to work.
Display shows
An attempt is being
"Atte"
made to start the stove
while it is still in the cool-
ing-down phase.
Only to be done by an approved flue
fitter: Flues that are not airtight can harm
your health. Seal the pipe fitting immedi-
ately (use Loctite 598 or equivalent prod-
uct) and/or replace the pipes.
Replace the seal. Only to be done by a
Qlima-approved technician
This is not an error. The stove is working in
eco mode. This mode can be changed with
the remote control
The stove requires a service. Contact a
Qlima-approved service technician. The
technician will carry out a service on the
stove and reset the notification.
Wait until the cooling down phase has
been completed before trying to reignite
the stove.