Water supply
ATTENTION
Risk of damage to the plant if water supply
is not of suitable quality.
Note: Impurities in the inlet water can dam-
age the unit. Kärcher recommends a water
filter with a mesh width of < 80 µm.
Quality requirements for tap water:
pH value
electrical conductivity
removable materials
filterable materials (grain
size below 0.025 mm)
Hydrocarbons
Chloride
Calcium
Total hardness
Iron
Manganese
Copper
free of bad odours
* Test volume 1litre, Settling time 30 min-
utes
** decalcification measures are necessary
if the values are higher
 The water inlet is to be connected to the
main water supply using a water hose.
– The water supply volume must be at
least 6200 l/h at least 0.15 MPa (with
float switch) or 0.01 MPa (without float
switch).
– Appliances without prepressure pump:
The water temperature must lie below
60 °C.
– Device with advance pressure pump:
The water temperature must be under
85 °C.
– The water supply must designed for
continuous operation.
– If the advance pressure is too high or in
case of peaks in the line system, it is
absolutely necessary to install a pres-
sure reducer.
Note: Operating procedures create short
term power sinkings. During unfavorable
net conditions other devices might be dis-
turbed.
ATTENTION
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
6.5...9.5
confusion regarding the power impedance
< 2000 µS/cm
present on your connection, please contact
< 0.5 mg/l *
your utilities provider.
< 20 mg/l
– For connection values, see technical
data and type plate.
< 20 mg/l
– The electrical connections must be
done by an electrician according to IEC
< 300 mg/l
60364-1.
< 85 mg/l **
– Current-carrying parts, cables and ap-
< 15 °dH **
pliances in the working area must be in-
< 0.5 mg/l
stalled in a defectless state and must be
< 0.05 mg/l
protected against water sprays.
– The electric connection must be de-
< 0.02 mg/l
signed for continuous operation.
– The electrical connection is made on
the control for the entire high pressure
cleaning system.
DANGER
To avoid accidents due to electrical faults
we recommend the use of sockets with a
line-side current-limiting circuit breaker
(max. 30 mA nominal tripping current).
ATTENTION
In order to avoid damage to the com-
pressed air drive by condensation wear
and lack of lubrication, install a mainte-
nance unit into the compressed air supply.
The maintenance unit consists of:
– Water separator
– Pressure regulator with manometer
– Proportional oiler
 Fill the proportional oiler with suitable
lubrication oil by unscrewing the reser-
voir and filling it with lubricating oil.
Electrical connection
Compressed air supply
13
-
EN
Initial Start-Up
 Rinse the firmly installed pipe at the in-
stallation site. Check that the entire high
pressure system is assembled correctly
and is not leaky.
 Check the function of the calcification
unit if necessary.
 Check the water supply for the required
feed volume and permissible tempera-
ture.
 Create the overflow drain line of the
swimmer tank.
 Create an over pressure line on the
safety valve.
 Check oil level of the high pressure
pump.

Warranty

The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.