Before Starting The Equipment - EINHELL GE-CL 18/1 Li E Originalbetriebsanleitung

Akku-universalbläser
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
K uncertainty .......................................... 3 dB (A)
Vibration a
......................................... ≤ 2.5 m/s
hv
K uncertainty ...........................................1.5 m/s
Weight: .......................................................1.5 kg
Important!
The equipment is supplied without batteries and
without a charger is allowed to be used only with
the lithium-ion batteries of the Power-X-Change
series!
The lithium-ion batteries of the Power-X-Change
series are allowed to be charged only with the
Power-X charger.
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
Anl_GE-CL_18-1_Li_E-Solo_SPK9.indb 15
Anl_GE-CL_18-1_Li_E-Solo_SPK9.indb 15
GB
tion is used.
3. Health damage caused by hand-arm vib-
2
rations if the equipment is used over a pro-
2
longed period or is not properly guided and
maintained.
4. Risk of eye damage if suitable safety goggles
are not worn.
This equipment generates an electromagnetic
fi eld during operation. Under certain circumstan-
ces this fi eld may actively or passively impede
medical implants. To reduce the risk of serious
or fatal injuries, we recommend persons with
medical implants to consult their doctor and the
manufacturer of the medical implant prior to using
the equipment.

5. Before starting the equipment

The equipment is supplied without batteries
and without a charger.
Warning!
Always remove the battery pack before starting
any work on the equipment.
5.1 Blower tube assembly
Note: As supplied, the blower tube at the motor
end (Fig. 2/Item 1a) and the curved blower tube
(Fig. 2/Item 1b) are joined together.
You can use the equipment to suit your needs
with either a 2-piece blower tube (as supplied) or
with just the short blower tube at the motor end
(see section 5.1.2).
5.1.1 Fitting the blower tube to the motor
(Fig. 3)
Fit the motor unit (Item 3) and the blower tube at
the motor end (Item 1a) together.
5.1.2 Removing the curved blower tube
(Fig. 4)
Turn the curved blower tube (Item 1b) out of the
end stop and pull it off the blower tube at the mo-
tor end (Item 1a).
5.1.3 Fitting the curved blower tube (Fig. 5)
Fit the curved blower tube (Item 1b) onto the
blower tube at the motor end which is already
fi tted to the motor (Item 1a). The locks (Item A) on
both sides must be pushed into the guides (Item
B) when you do this. Turn the curved blower tube
when it has reached the stop on the blower tube
at the motor side to secure it.
- 15 -
06.03.2020 09:31:17
06.03.2020 09:31:17