Technical description
7.1

Components

The refrigerant circuit of the roof air conditioner consists of five main compo-
nents (fig. 1, page 2):
z Compressor (1)
The compressor draws in the R407c refrigerant used and compresses it.
This raises the pressure and therefore the temperature of the refrigerant.
z Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flowing
past absorbs the heat and the hot refrigerant gas cools down and
becomes liquid.
z Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them. The
refrigerant absorbs the heat and vaporises.
z Blower (4)
A blower distributes the cooled air within the vehicle through an air outlet
unit.
z Solenoid valve (5)
The solenoid valve allows the cooling cycle to be reversed and the air
feeding in to be heated.
Overview of all parts: fig. b, page 7.