• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Storage chapter.

Available accessories

Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation
Optional hygrostat for TTK 400
External hygrostat HG 130
Condensate pump TTK 400 incl. installation
kit
Starting current limiter ASB 3500
Air filter with handle piece for TTK 400
Air filter for TTK 400

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damage.
• Check the on-site fusing.
• If you operate the device with a hygrostat (optional), check
the set value. In order for the construction dryer to operate,
the humidity level at the installation site needs to be higher
than the set value. Set the hygrostat to a lower value.
The device is running, but there is no formation of
condensate:
• Check whether the condensation drain hose is positioned
correctly.
• When using the condensate pump: Check the
condensation tank and hoses for dirt.
• Ensure that the relative room humidity complies with the
technical data.
• If you operate the device with a hygrostat (optional), check
the set value. In order for the construction dryer to operate,
the humidity level at the installation site needs to be higher
than the set value. Set the hygrostat to a lower value.
B - 30
• Check the air filter for dirt. If necessary, clean or replace
• From the outside, check the condenser for dirt (see
• The device might carry out an automatic defrost. During
The device is loud or vibrates:
• Check whether the device is set up in a stable and upright
Condensate is leaking:
• Check the device for leaks.
The compressor does not start:
• Check the room temperature. Observe the device's
Article number
• Check whether the overheating protection of the
7.430.000.935
6.100.002.045
6.100.003.010
• The device might carry out an automatic defrost. During
6.100.002.030
7.160.000.010
The device gets very warm, is loud or is losing
7.160.000.007
performance:
• Check the air inlets and air filters for dirt. Remove external
• From the outside, check the device for dirt (see chapter
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
dehumidifier TTK 400
the air filter.
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
automatic defrost, the device does not dehumidify.
position.
permissible operating range according to the technical
data.
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.
automatic defrost, the device does not dehumidify.
dirt.
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.