Note 1 for operation: Optimal room temperatures
At room temperatures below 12 °C, the room should be heated
in order to optimise energy efficiency and to reduce drying
periods. For this purpose, preferably use an electric heater. Do
not under any circumstances use direct oil or gas heaters
(devices without flue pipe connection) as these release large
amounts of water vapour into the room air. This will extremely
extend the drying periods and increase energy costs. The ideal
operating temperature for efficient drying is between 15 –
 25 °C. In order to carry out a proper dehumidification process
and to optimise flowrates, position the electric heater as far
away from the dryer as possible.
Note 2 for operation: Air distribution with fans
If the areas to be dehumidified are in several different rooms,
we recommend using one fan per room in rooms where no
dehumidifier has been set up. This will significantly reduce the
drying period. Always keep the doors between the individual
rooms open. Otherwise, a dehumidifier has to be installed in
each room. All windows and exterior doors must to be shut
during the drying process!
TTK 400
Follow the manual
This symbol indicates that the operating manual must
be observed.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.
EN

Residual risks

Danger
Refrigerant R454C!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames
and other ignition sources. No smoking.
P381 – Eliminate all ignition sources if safe to do so.
P403 – Store in a well-ventilated place.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.