FUSE CHECK/REPLACEMENT/RESET

1.
Drive the machine on a level ground and engage the
parking brake with the pedal (3) and the lever (4).
2.
Turn the ignition key (72) to "0".
3.
Open the hood (7).
4.
Disconnect the battery connector (46).
Lamellar fuse check/replacement
5.
Remove the fuse box cover (51).
6.
Check/replace the relevant fuse among the following (Fig.
19):
F1: Main fuse (key circuit) (15 A)
F2: Filter shaker motor fuse (25 A)
F3: Manual vacuum system fuse (40 A) (optional)
F4: Vacuum system motor fuse (30 A)
F5: Horn and pivoting light fuse (10 A)
F6: Working light fuse (10 A) (optional)
7.
Remove the electrical component box cover (55).
8.
Check/replace the following fuse (Fig. 20):
FT: Drive system fuse (70 A)
Circuit breaker check
9.
Check for deactivation of one of the following fuses, then
reset it after the relevant motor has cooled down:
FA: Main broom motor circuit breaker (30 A) (52)
FB: Side broom motor circuit breaker (10 A) (53)
Assembly
10.
Assemble the components in the reverse order of
disassembly.
F1 F2
SR 1100S B
146 2494 000(2)2007-02 A
USER MANUAL
F3
F4
F6
F5
Figure 19
Figure 20
ENGLISH
F7
F8
S311413
FT
S311414