overloading and blocking. The pump is switched
off automatically by the thermostat if overheating
occurs and is switched on again automatically
after cooling.
6. Operation
Install the equipment on a solid and level
n
surface.
Fill the pump housing with water via the water
n
filler screw (4). Filling the intake line accelerates
the intake process.
Open the discharge line.
n
Connect the mains cable. The intake process
n
starts automatically; water can be suctioned in
for up to 5 minutes (maximum suction height).
If the pump is removed again after use, it must
n
always be refilled with water whenever it is
connected up and used again.

7. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, however,
we recommend that you regularly check and care for
the product.
Important!
The equipment must be disconnected from the
power supply (pull the power plug) prior to
performing any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect the
n
discharge line to the water line and disconnect
the suction hose. Open the water line. Switch on
the equipment several times for approx.
two seconds. This should resolve the majority of
clog-related problems.
Replacing the mains cable: Important:
n
Disconnect the equipment from the power
supply! A defective mains cable may only be
replaced by a qualified electrician.
There are no parts inside the equipment which
n
require additional maintenance.
8.2 Storage
If the pump is not going to be used for a long
n
time or has to be removed for the winter months,
rinse it out with water, empty it completely and
allow it to dry.
The equipment must be completely drained
n
before it is subjected to frost.
After long stoppages, make sure the rotor turns
n
correctly by briefly switching the pump on and
off.

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
n
Article number of the machine
n
Identification number of the machine
n
Replacement part number of the part required
n
For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
10. Storage
Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing
temperature. The ideal storage temperature is
between 5 and 30 °C. Store the electric tool in its
original packaging.