Anleitung_BG_SP_400_RB_SPK1:_
You can then see whether the equipment
switches on and off.
Make sure that the distance between the floating
switch head and the cable holder is not too small.
If the distance is too small, there is no guarantee
that the equipment will work correctly.
When adjusting the floating switch, make sure
that the floating switch does not touch the bottom
before the equipment is switched off. Important!
Risk of dry running.

7. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning, maintenance and
ordering of spare parts
Important!
Unplug the power plug prior to any maintenance
work.
For mobile applications, the equipment should be
cleaned with clear water after every usage.
For stationary installation, it is recommended that
you check the floating switch for proper
functioning every three months.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in the
housing.
Remove sludge from the shaft bottom and clean
the shaft walls every 3 months.
Use clear water to remove deposits from the
floating switch.
8.1 Cleaning the filter (Figs. 7 and 8)
In order to protect the equipment and the impeller
from severe soiling, an additional filter has been
installed in the bottom intake cage. Please proceed
as follows when cleaning the filter:
1. Gently press the lateral tab (A) in the direction of
the arrow until the intake cage (5) can be
disconnected from the pump.
2. Remove the filter (B) and wash it out under
running water.
3. Now insert the filter back into the intake cage and
reconnect the intake cage to the equipment.
8.2 Maintenance
There are no parts inside the equipment which
require additional maintenance.
12.04.2011
9:57 Uhr
Seite 11

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.