Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Care; Environmental Advice - VOLTCRAFT CT-2 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RJ 11-Kabel
- to test cables with RJ 11 plug connections, please use the two
reducing parts RJ 45/RJ 11. the reducing parts are simply insert-
ed into the wanted RJ 45 jack of the cable tester or of the
Remote-Terminators. - the testing process is similar to the one of
the RJ 45 cables but now only the 6 or 4 LEDs in the middle on
the incoming side are gated.
BNC-cables
- for the testing of coaxial cables with BNC-plugs, please use the
two RJ 45/BNC-adapter cables which are included in the scope of
delivery. The adapter cables are just plugged into the respective
RJ 45 jack of the cable tester or the Remote-Terminators and can
be connected with the BNC-connection plug for test purposes.
- because of the fact that at this test the inner conductor is dis-
played LED 1 and the shielding with LED 2 we recommend to do
this test in the manual mode.

Maintenance and care

Except of a battery change from time to time, the cable tester is is
maintenance free. You can find information on the battery change
in the respective chapters of the operation manual. On the outside,
the cable tester should only be cleaned with a soft, dry cloth or
brush. Under no circumstances use aggressive detergents or chem-
ical solvents, because the surfaces of the housings could be dam-
aged. Furthermore the fumes are explosive and hazardous to health.

Environmental advice

Disposal of used batteries/accumulators!
You as user are legally obliged (battery regulation) to return all
used batteries and accumulators; a disposal into the normal
house waste is prohibited!
21