ATTENTION: All adjustments and modifications to be performed on the gas installation and
connection of the device should be performed by authorized people.
ADJUSTMENT ACCORDING TO DIFFERENT GAS TYPES
 If the device is connected to gas installation, close main gas inlet valve.
Replacement of burner nozzles (fig. B)
1. Open the cabinet cover of the fryer. (7178.0510/7178.0515/7178.3045/7178.3050)
Unscrew the front panel (7178.0080/7178.0085)
Unscrew the nozzle (3) at the burner inlet using a suitable wrench.
2. Replace nozzle (3) with a nozzle suitable one for the gas type.
3. Adjust the pilot flame (1) by turning bolt nut (2)
 The venturi (Gas/Air tube) adjust part gap should be 10 mm for LPG gas type, 20 mm
for NG gas type. ( Fig.1)
 After adjust of venturi tube gap, tight with a suitable wrench.
D. OPERATOR INSTRUCTIONS AND ATTENTION POINTS
 Before cooking with the fryer, operate it with no load (by pouring water in its chamber)
for a while. Thus, the protection oil on it will disappear and it will become ready to use.
 When you do not cook, keep the adjustment button on pilot position. It will provide a
more economical usage for you.
Never operate the fryer without oil. Check whether the chambers are full with oil before
use.
 When the oil level descends to minimum, refill oil.
 If you will not use the device for a long time, cover it with suitable oil and keep away
from moisture.
 Do not operate the device with its back funnel mouldings removed or closed.
Figure 1