A safety bond which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!
Attention: After every 16 WP-60 panels, the fixtures must have a renewed connection with the power mains.
Attention: A booster must be installed after every 16 WP-60 panels for signal enforcement.
Attention: Control for a maximum of 100 WP-60 panels via optional FUTURELIGHT LC-01 controller.

Connection with the mains

Connect the device to the mains via optional power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

Connection of the devices

DANGER TO LIFE!
International
L
N
21/42