10

Technical data

10
Technical data
10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Shaft insulation:
• Transmission length:
• Interference immunity:
• Emitted interference:
• Approvals:
• Location classes DNV:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
5)
9...30 VDC
(HTL-P, TTL - version R)
5)
5 VDC ±5 % (TTL)
≤100 mA
300...2500 (as ordered)
90° ±20°
30...70 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL-P (power linedriver)
TTL/RS422
(as ordered)
2.8 kV
≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
EN 61000-6-2
EN 61000-6-3
CE, UL
Temperature: D
Humidity: B
Vibration: B
EMC: B
Enclosure: C