Continuous or extended operation

In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In continuous
mode it is not needed to empty the water collecting container.
Proceed as follows:
1. Remove the water collecting container from the device.
2. Put the draining hose (3) through the hole
enclosure and pull it out of the device on the other side
3. Re-insert the collecting container in the device.
4. Close the hinged enclosure cover.
5. Place a large collecting container below the water draining.
Or:
Extend the water draining using a garden hose to pipe the water
into a drain channel.
Pay attention to the following:
Make sure that the water can flow out unhindered.
Pipe the water preferably to a drain which is positioned at
a lower level.
Make sure that the hose remains in its position, is routed
with a descending gradient, is not kinked or wound up.
T
r
T
r
Power off the device and disconnect the mains
plug before each transport.
Always transport the air dehumidifier in upright (vertical) position
to prevent compressor damages.
Hint: If you have transported the air dehumidifier in
another than upright position (horizontal or tilted),
allow the air dehumidifier to stand in upright position
for at least one hour before starting it up.
18
a
n
s
p
o
r
t
a
n
s
p
o
r
t
C
C
Turn off the device and disconnect the power
plug before each cleaning and maintenance
work.
Maintenance and repair work other than those described in this
chapter is only allowed to be carried out by service staff.
Only use genuine spare parts. Other than genuine parts may
in the
result in unpredictable damages and injury.
.
A contaminated filter
deteriorates the performance of the air dehumidifier,
results to contamination inside the device.
Clean the filter in regular intervals depending on the
operating conditions.
1. Remove the enclosure door (4).
2. Pull out the three fixing bars (5)
from the enclosure door for cleaning
Slight contamination
Use a vacuum or slightly knock off the filter to clean it.
l
e
a
n
i
n
g
a
n
d
m
a
i
n
t
e
n
l
e
a
n
i
n
g
a
n
d
m
a
i
n
t
e
n
Cleaning air filter

Removing the filter

. Remove the filter (6)
a
n
c
e
a
n
c
e
.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ale 800 n

Inhaltsverzeichnis