7.2 Factory reset

Factory reset restores the factory
defaults. Before the reset, make sure the
appliance is in setting mode.
Press and hold Previous and Next for 5
seconds.
The displays shows _ _ _ for about 5
seconds.
The appliance returns to the programme
selection.
Factory reset does not reset
the cycle counter and the
wireless connection setup.

7.3 Cycle counter

You can view the number of completed
dishwashing cycles in the cycle counter.
1. Press and hold the on/off button until
the dishwasher is activated.
Water hardness
German de‐
grees (°dH)
47 - 50
43 - 46
37 - 42
29 - 36
23 - 28
19 - 22
15 - 18
11 - 14
4 - 10
<4
1) Factory setting.
2) Do not use salt at this level.
Regardless of the type of detergent
used, set the proper water hardness
French de‐
mmol/l
grees (°fH)
84 - 90
8.4 - 9.0
76 - 83
7.6 - 8.3
65 - 75
6.5 - 7.5
51 - 64
5.1 - 6.4
40 - 50
4.0 - 5.0
33 - 39
3.3 - 3.9
26 - 32
2.6 - 3.2
19 - 25
1.9 - 2.5
7 - 18
0.7 - 1.8
<7
<0.7
2. Press and hold Previous and Next
for 5 seconds.
The displays shows uC and then the
number of cycles.
Press any button to exit the cycle
counter.
After reaching 65535, the
cycle counter restarts.
7.4 The water softener
The water softener removes minerals
from the water supply, which would have
a negative effect on the washing results
and on the appliance.
The higher the content of these minerals,
the harder your water is. Water hardness
is measured in equivalent scales.
The water softener should be adjusted
according to the hardness of the water in
your area. Your local water authority can
advise you on the hardness of the water
in your area. Set the right level of the
water softener to assure good washing
results.
mg/l (ppm)
Clarke
degrees
835 - 904
58 - 63
755 - 834
53 - 57
645 - 754
46 - 52
505 - 644
36 - 45
395 - 504
28 - 35
325 - 394
23 - 27
255 - 324
18 - 22
185 - 254
13 - 17
70 - 184
5 - 12
<70
< 5
level to keep the salt refill indicator
active.
Water soften‐
er level
10
9
8
7
6
1)
5
4
3
2
2)
1