WARNING
CHECK THAT THE PRESSURE CONTROL HOSE IS ALWAYS CONNECTED
TO THE INFLATOR AND TO THE INFLATABLE ITEM
3. Connect the power cable to the appropriate socket.
4. Press the main switch of the inflator (Point 1 Fig.1). When
the green light comes on, the inflator is ready to work.
5. Press the ON/OFF
switch.
6. The display will show the preset pressure that the inflatable item must reach. If it needs to be
changed, refer to chapter 8 "HOW TO CHANGE THE PRESSURE SETTINGS".
7. Press the AUTO CYCLE button. The 2 LEDs light up and after 2 seconds the GE 1800 ROMA will start
to inflate.
8. HOW TO CHANGE THE PRESSURE SETTINGS
1. CONNECT THE POWER CABLE TO THE SOCKET.
2. TURN ON THE MAIN GREEN SWITCH
3. ENSURE THAT THE AUTOCYCLE IS SWITCHED OFF
4. FOLLOW THE STEPS BELOW TO ADJUST THE PRESSURE:
A. PRESS MODE to select the unit of measurement
(mbar, psi, kPa, bar): press the MODE button multiple
times, until you find the desired unit.
B. Changing the inflation pressure using the SET+/
SET- buttons: when a button is pressed for 2 seconds,
the display starts blinking and the pressure can be
adjusted by pressing the SET+/SET- buttons.
After 2 seconds, the display stops blinking and the pressure is memorised. The pressure can be
set between 50 and 360 mbar.
C. Changing the filling pressure: when the MIN button is pressed for 3 seconds, the display starts
blinking. The value may be changed by using SET+ and SET-. After 2 seconds, the display stops
blinking and the value is memorised. The filling pressure may be adjusted from 30 to 70 mbar with
respect to the operating pressure. Example: if you wish to reach an inflation pressure of 250 mbar
and the refilling value is set to 50 mbar, when the pressure of the inflatable item reaches 200 mbar,
the GE 1800 ROMA switches back on and the ARS system brings the pressure of the inflatable item
to 250 mbar.
D. Changing the deflation pressure: when the MAX button is pressed for 3 seconds, the display
starts blinking. The value may be changed by using SET+ and SET-. After 2 seconds, the display
stops blinking and the value is memorised. The deflation pressure may be adjusted from 30 to 70
mbar with respect to the operating pressure.
Example: if you wish to reach an inflation pressure of 250 mbar and the deflation value is set to 50
mbar, when the item reaches 300 mbar, the ARS system opens the deflation valve until it reaches
250 mbar.
E. After the changes press AUTO CYCLE: The 2 LEDs light up after 2 seconds and the red LED turns
off; the green LED indicates that the GE 1800 ROMA will automatically start to inflate/deflate and
refill to the pressure. With the automatic cycle activated (LEDs on), the unit automatically checks the
pressure of the inflatable item.
12
WARNING
IN THE EVENT OF A POWER FAILURE DURING OPERATION, THE DEVICE IS ABLE TO KEEP THE WORKING SETTINGS
STORED AND THEN RESTART WHEN POWER IS RESTORED.
fig.2
9. TROUBLESHOOTING
PROBLEM
The inflator does
not start
fig.3
The inflator is
stopped
The inflator does
not stop
The ARS system is
not working/ The
pressure measured
on the display does
not change
9.1 ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.
POSSIBLE CAUSE
The power cable is not connected to
the socket
The main GREEN switch is off
Ask the SCOPREGA service to replace
The power cable is damaged
The power cable is not
connected to the socket
The main switch is off
Wait until the ARS motors cool down.
Over-temperature
The inflator will restart automatically.
The pressure sensor hose (blue) is not
properly connected to the pump or
valve of the inflatable item
The pressure sensor hose (blue) is not
properly connected to the pump or
valve of the inflatable item
POSSIBLE SOLUTION
Connect it correctly
Press the switch
or repair the cable
Connect it correctly
Press the switch
Connect the hose correctly
Connect the hose correctly