WATER CONDENSATION DRAINAGE
When there is excess water condensate inside the unit, the air conditioner stops running and the
Power Control button flashes with a red light. This warning light indicates that the water condensate
needs to be drained using the following procedures:
Manual Draining in Cooling and Dehumidifying Modes
Water may need to be drained in high humidity areas.
1.
Unplug the unit from power source.
2.
Place a shallow pan under the lower rubber drain plug.
See diagram.
3.
Remove the lower rubber drain plug.
4.
Water will drain out and collect in the shallow pan.
5
After the water is drained, replace the lower rubber drain
plug firmly.
6.
You can now turn on the unit.
If you find that there is a high volume of condensate and a shallow pan is not enough for your use,
you can use a large pan to drain. Follow the below instructions carefully:
1.
Find a flat, stable board that is up to 1" thick. The base
could be a wooden board purchased from your local
hardware store, with minimum base dimensions of
20" (length) x 17" (width) x 1" (thickness).
2 .
The base should be large and sturdy enough to fit the
Portable Local Air Conditioner on top. The air conditioner
must be stable and not rock or move when positioned on
this base and not easily topple over.
3.
Drain the water from the lower drain plug as needed into
a larger pan or through a drain tube. If using a drain tube,
you can purchase vinyl tubing with an outside diameter
of 5/8" and an inside diameter of 1/2".
Remember the drain tube must be positioned lower than
the drain plug so the water condensate does not
flow backward back into the air conditioner.
WARNING: For safety reasons, the Portable Local Air Conditioner must NOT be positioned on a
base that is higher than 1" from the floor. This is only recommended if you have a stable, flat base to
position the Portable Local Air Conditioner on safely.
Plastic Cap and
Lower Drain Plug^
Plastic Cap
and Lower
Drain Plug
EN
13
Shallow Pan
(Not included)
Large Pan
Wooden Board
(Not included)
Height: up to 1"
^External Dia.: 17 mm

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hc09cesvwk

Inhaltsverzeichnis