Herunterladen Inhalt Inhalt Diese Seite drucken

ecofort ecodry Pro 35C Bedienungsanleitung Seite 54

Professioneller luftentfeuchter für die bautrocknung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Never insert foreign objects into the device.
• Unplug the product immediately if it emits strange noises, odors or smoke.
• Make sure that no foreign objects cover or block the air inlet/outlet. Blockages can lead to
fires, electric shocks or damage to the product.
• Unplug the product when it is not in use.
• Before the device is moved, make sure it is switched off and unplugged.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified person in order to avoid a hazard.
• The appliance shall be installed in accordance with national wiring regulations.
• The machine is designed only for use with R290 (propane) gas as the designated refrigerant.
• THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN
SHOULD ATTEMPT TO SERVICE!
• The lack of smell does not indicate a lack of escaped gas.
• No open flames, cigarettes or other possible sources of ignition should be used in the
vicinity of the machine.
• Component parts are designed for propane and non-incentive and non-sparking.
• Component parts shall only be replaced with identical repair parts.
THE DEVICE MAY ONLY BE INSTALLED IN A ROOM WITH A MINIMUM FLOOR AREA
OF 10 m².
R290 is a flammable gas that is heavier than air. On this basis, if the gas leaks from the unit, the
concentration will be the highest at ground level. However, the gas can be lifted (e.g. by draught,
fan etc.) to higher levels. The R290 (propane) used in this unit has no odor.
Do not use the device in a room with an open flame, other high-level heat sources (e.g. cigarettes,
candles, etc.) or electrical discharges. Install the machine in a room which can be ventilated when
necessary and where gas accumulation is not possible.
If R290 (propane) is detected in the room, or a leak is suspected, do not allow unauthorized
persons to search for the source of the leak. In such cases, evacuate all people from the room,
open the windows, leave the room and notify your local fire