Instruction on mounting and use

Note: The parts marked with the symbol "(*)" are optional
accessories supplied only with some models or otherwise not
supplied, but available for purchase.

Use

The hood is conceived for the suction of cooking fumes and
steam and is destined only for domestic use.
The hood is designed to be used either for exhausting or filter
version.
Extraction version
In this case the fumes are conveyed outside of the building by
means of a special pipe connected with the connection ring
located on top of the hood.
Diameter of the exhausting pipe must be equal to that of the
connection ring (Ø 150 mm).
Attention ! The exhausting pipe is not supplied and must be
purchased apart.
In the horizontal runs the exhausting pipe must be slightly
slanted (about 10°) and directed upwards to vent the air easily
from the room to the outside.
Attention! If the hood is supplied with active charcoal filter,
then it must be removed.
Connect the hood and discharge holes on the walls with a
diameter equivalent to the air outlet (connection flange).
!
Use a duct of the minimum indispensable length.
!
Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
Attention ! If the hood is supplied with carbon filter, then
it must be removed.
Filtration version
The aspirated air will be degreased and deodorised before
being fed back into the room.
In order to use the hood in this version, you have to install a
system of additional filtering based on activated charcoal.

Installation

• The minimum distance between the supporting surface for
the cooking equipment on the hob and the lowest part of the
range hood must be not less than 50 cm / 65 cm (for Australia
and New Zealand) from electric cookers, and 65 cm from gas
or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.

Electrical connection

The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING! Before re-connecting the hood circuit to the
mains supply and checking the efficient function, always
check that the mains cable is correctly assembled.
The hood is provided with a special power cable; if the cable
is damaged, request a new one from Technical Service.
Range hoods and other cooking fume extractors may
adversely affect the safe operation of appliances burning gas
or other fuels (including those in other rooms) due to back flow
of combustion gases. These gases can potentially result in
carbon monoxide poisoning. After installation of a range hood
or other cooking fume extractor, the operation of flued gas
appliances should be tested by a competent person to ensure
that back flow of combustion gases does not occur.

Mounting

Before beginning installation:
Check that the product purchased is of a suitable size for
the chosen installation area.
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.

Operation

Control panel with 6 buttons
To select the functions of the hood just touch the commands.
T0=
Motor key OFF (stand by) – excludes the electronics –
reset wash/replace filters signals.
MOTOR OFF
Press briefly to switch the motor off.
RESET FILTERS SIGNALS
In functioning mode, after carrying out filter maintenance,
22