en - Technical data

Voltage versions and electrical data

3N AC 400 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
3 AC 230 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section

Plumbing

Cold water connection

Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose included in scope of supply

Hot water connection

Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Drainage (DP)

Maximum waste water temperature
Drain connection (on machine)
Maximum drainage rate

Air intake

Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of an appliance).
There must be sufficient air intake to the installation site to match the air outlet volume.
48
Washing machine
3N AC 400 V
50 Hz
3 x 16 A
Type B
8,2 kW
5 x 1,5 mm²
Washing machine
3 AC 230 V
50 Hz
3 x 20 A
Type B
8,2 kW
4 x 2,5 mm²
Tumble dryer
3N AC 400 V
50/60 Hz
3 × 16 A
Type B
8,2 kW
1,5 mm²
Tumble dryer
3 AC 230 V
50/60 Hz
3 × 25 A
Type B
8,2 kW
2.5 mm²
100 - 1000 kPa (1 - 10 bar)
10 l/min
3/4"
1550 mm
70 °C
100 - 1000 kPa (1 - 10 bar)
10 l/min
3/4 "
1550 mm
95 °C
External diameter 22 (DN 22)
26 l/min
237 cm²