Safety Notes

6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6 The hot and cold supplies must be of equal
pressures.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms!
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
• In case of problems with the continuous water heater
or of greatly varying water pressures, you must install
the water limiter (comprised in the delivery, article
number 97510000) in the cold water supply.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
anti-pollution function
The product is exclusively designed for drinking water!
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Do not use silicone containing acetic acid!
Safety Function (see page 16)
The desired maximum temperature for
example max. 42º C can be pre-set thanks
to the safety function.
Adjustment (see page 17)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Maintenance (see page 21)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot to
total cold.
• The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN
EN 1717 in accordance with national
or regional regulations (at least once a
year).
Operation (see page 18)