Werbung

Symptom
Possible cause
Dry-running
protection has
tripped
Overcurrent
protection has
tripped
The pump is
not working
No power supply
Abnormal voltage
or voltage drop
at start-up
Locking
of the float
switch
The pump is running
but gives little or no
water
The pump is
running but
giving little
Incorrect direction
or no water
of rotation of the
motor
Troubleshooting

Problem solution

Wait until there is enough water in the well
for the pump to start automatically
Check why the overload occurred. Eliminate
the cause. Wait until the motor cools down
and switch on the pump using the switch built
into the safety box
Check that the electrical plug of the pump
is properly inserted in the electrical socket
Check the fuses in the house and any type
of installation fuses that can cut off the mains
supply
Check that there is power in the area around
your home - electricity may be disconnected
by the power company in a wider area
Check the voltage. Check that the cross-section
of the power supply cable is appropriate
Check that the float switch has not snagged
on the well wall or any object
Odłącz pompę od zasilania elektrycznego.
Po wyjęciu pompy ze studni oczyść filtr
Swap the two wires of the supply cable on
the power strip (only for three-phase motors)
Incorrectly connected conductors in the
protection box (only if they have been
previously disconnected by the user).
Make the correct connection. Commission
the correct connection to a service centre
25