Drive Test GmbH München
4.7

SHORT OPERATING INSTRUCTIONS

4.7.1 Measuring

Step
Function
0
Turn off
1
Turn on
2
Note
3
Measuring position
4
Start measuring
5
Start closing
process
6
Is measurement
valid ?

4.7.2 Data evaluation

Step
Function
1
Connect
2
Upload
3
Enter properties
4
Print
Version 7.1
Handbuch / Manual FM300
Instruction
Press operating button for longer than 2 sec.
Connect sensor to display unit
Briefly press operating button
Set limit if needed
Yellow LED flashes slowly
Note memory no. of display unit, together with point
of measurement
Hold static sensor side to static side of closing
system
Briefly press operating button
System tares, Yellow LED flashes fast
Start closing and wait for end of measurement;
green or red LED is on (OK/ not OK)
Yes: Briefly press operating button
No: Press operating button for a longer time
Instruction
Start PinchPilot
Connect display unit to PC
Briefly press operating button of display unit
Load measurements into the PC (tool bar: cube
with red arrow)
Select measurements (tool bar: arrows)
Enter properties
Start print-out (tool bar: printer symbol) or start
export