Herunterladen Inhalt Inhalt Diese Seite drucken

Nibe EME 20 Installationsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für EME 20:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

CONNECTING EME 20
CONNECTING TO INVERTER
Connect the cables to the converter according to the
diagram below.
External connection cable must be 0,5 mm² up to 50 m,
e.g. EKKX, LiYY or similar.
NOTE
The front cover on the inverter must not be
opened. Connection can be performed via the
dedicated cover under the inverter, as illus-
trated. Use the enclosed terminal block sup-
plied with the rectifier. Note how the cables
are connected in the terminal block!
10
All manuals and user guides at all-guides.com
CONNECTION TO NIBE PRODUCT
SMO 20
On SMO 20, the cable with pre-installed connectors
(part no. 718 576, length 3 m) must be connected to
socket X8 on the display unit and on the terminal block
AA23:1-4 on the EME 20 board.
Terminal block AA23:9-10 on the EME 20 board is con-
nected to terminal block 1-2 on the inverter.
L N
1
1
0
PE
2
3 4
X8
LEK
X8
Length 3 m
Green = GDN
1
2
3
4
White = A
Brown = B
Yellow = 12V
Inverter
SMO 20
EME 20
5
6
7
8
9
10
11
AA23
1
2
EME 20 | GB