Herunterladen Inhalt Inhalt Diese Seite drucken

LIMIT DM 620 Bedienungsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
Relative value measurement
P-MAX / P-MIN
Peak measurement
mV, V
Voltage units: millivolt, volt
HA, mA, A
Current units: microampere, milliampere, ampere
nF, μF, mF
Capacitance units: nanofarad, microfarad, millifarad
MAX/MIN
Maximum/Minimum measurement
Electrical symbols
Symbol
Description
Warning. Risk of Danger. Important information. See manual.
High voltage warning.
DOUBLE INSULATION or REINFORCED INSULATION.
Do not discard this electrical/electronic product in domestic
household waste.
Both direct and alternating current.
Earth (ground) Terminal.
Conforms to European Union directives.
It is applicable to testing and measuring circuits connected
CAT III
to the distribution side of the building's low-voltage MAINS
installation.
It is applicable to testing and measuring circuits connected to
CAT IV
the source of the building's low-voltage MAINS installation.
FUNCTION DIAL AND FUNCTION BUTTONS
1. Function Dial
Dial Position
Description
OFF
Power off
AC/DC voltage measurement/Frequency and duty ratio
measurement
AC/DC millivolt voltage measurement/Frequency and duty ratio
measurement
D i o d e te st /Co nt i n u i ty te st / Re s i st a n ce m e a s u re m e nt /
Capacitance measurement
Hz%
Frequency and duty ratio measurement
AC/DC microampere current measurement/Frequency and duty
ratio measurement
AC/DC milliampere current measurement/Frequency and duty
ratio measurement
GB