Herunterladen Inhalt Inhalt Diese Seite drucken

LIMIT DM 620 Bedienungsanleitung Seite 17

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
12. Non-contact voltage (NCV) detection (P 14)
DM 620
USB
P 14
12.1 Turn the function dial to the NCV position.
12.2 Put the NCV detector (top left corner of the meter) close to the wire (AC) under test.
12.3 If the voltage of the wire is ≥50 V RMS (frequency: 50/60 Hz), the red indicator light will be on
and the buzzer will beep. If no voltage is detected, the LCD will display "EF". As the intensity of
the detected voltage increases, more segments "-" will be displayed, and the frequency of buzzer
beeping and red indicator light flashing will increase.
Caution:
The detected voltage level varies with the distance between the NCV detector and the wire under
test.
The detected voltage level is for reference only, not for specific measurement. The frequency of the
detected voltage should be 50/60 Hz.
Hold the meter casing for non-contact voltage detection.
13. USB data transmission (P 15a, P 15b)
P 15a
13.1 Pull out the USB sealing cover at the back of the meter (Picture 15a).
13.2 Insert the USB communication module into the USB access port of the meter and the LCD will
display "
" (Picture 15b).
13.3 If USB data transmission is not needed during measurement, long-press the
out the USB module to disable data transmission, and "
P 15b
" will disappear.
button or pull
USB
15
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Luna-3957

Inhaltsverzeichnis