Herunterladen Inhalt Inhalt Diese Seite drucken

Power Board Fuse Replacement; Heating Element Safety Thermostat Reset - Ferroli EGEA 200 LT Handbuch Für Betrieb Und Installation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 222

9.1 Power board fuse replacement

Proceed as indicated below (reserved for qualified technical per-
sonnel only):
• Disconnect the power to the equipment.
• Remove the top cover of the equipment and then the power
board cover.
• Remove the fuse cap, then the fuse, using a suitable screw-
driver.
• Install a new IEC-60127-2/II certified time-delay 5 A fuse
(T5AL250V), then refit the protective cap.
• Reassemble all the plastics and make sure the equipment is
correctly installed before powering it.

9.2 Heating element safety thermostat reset

This equipment has a manual-reset safety thermostat connect-
ed in series with the heating element immersed in water, which
interrupts the power supply in case of overtemperature inside
the tank.
If necessary, proceed as follows to reset the thermostat (re-
served for qualified technical personnel):
• Unplug the product.
• Remove any air ducts.
• Remove the top cover by first undoing the locking screws (fig.
47).
• Remove the front panel and manually reset the tripped safety
thermostat (fig. 48). In case of intervention, the central pin of
the thermostat comes out by about 2 mm.
• Refit the previously removed top cover.
EN
128
fig. 46
cod. 3541T600 - Rev. 08 - 12/2021
EGEA
200 LT - 260 LT - 200 LT-S - 260 LT-S
fig. 47- Top cover removal
fig. 48- Front panel removal

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Egea 260 ltEgea 200 lt-sEgea 260 lt-s

Inhaltsverzeichnis