9. Submerge the fill opening in the remainder of the
fluid, and using a wrench, rotate the Drive Shaft to
purge any remaining air from the system.
10. Remove the mechanism from from the fluid and use
the Tee Wrench to push the Piston Stop Assembly
slowly downward until fluid flows from the fill
opening.
LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For International – No. C16–C3–A29
After each 20 000 cycles, or as experience indicates, drain
and refill the Impulse Unit Drive Assembly as instructed
in this manual using the Fluid Replacement Kit
(Part No. EQ106S–K400). Lubricate the hex drive
and the output shaft before assembly.
Model
Type of
Grip
1100P–EU
pistol
1410P–EU
pistol
1900P–EU
pistol
H
Tested in accordance with ANSI S5.1–1971 at free speed
♦ Tested to ISO8662–1 loaded with frictionbrake to 9 RPM
ADJUSTMENTS
(Dwg. TPD1265)

PLACING TOOL IN SERVICE

Ingersoll–Rand No. 67
Ingersoll–Rand Fluid Part
No. EQ106S–400–1
SPECIFICATIONS
Chuck/
Free
Drive
Speed
in.
Soft Draw
ft–lb (Nm)
1/2
5 000
35–60 (48–82)
1/2
6 000
40–70 (54–95)
1/2
5 000
(68–116)
11. Thread the Oil Plug with the Oil Plug Seal and Seal
Support into the mechanism until it is snug.
12. Using a 2 mm hex wrench, turn the Torque Adjustment
Screw clockwise until it stops. This is the maximum
torque position.
13. Wipe the outside of the mechanism dry and clean and
remove the Oil Chamber Plug. Using the syringe,
withdraw 0.85 cc of fluid from 1100P–EU models, 0.85 cc
of fluid from 1410P–EU models and 1.20 cc from
1900P–EU models.
14. Install the Oil Chamber Plug and tighten it between 20
and 25 in–lb (2.3 and 2.8 Nm) torque.
15. Position a new Hammer Case Gasket on the Motor
Housing and install the assembled mechanism on the
rotor shaft.
16. Place the Hammer Case Cover over the Drive Shaft
against the Housing and Gasket. Install the three
Hammer Case Cap Screws and Lock Washers. Tighten
each Screw between 45 an 50 in–lb (5.1 and 5.6 Nm)
torque.
17. Install the Rubber Housing Boot on the tool.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
Recommended
Torque Range
Hard Slam
ft–lb (Nm)
60–90
(82–122)
71–120
(97–163)
50–85
86–146
(117–199)
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)
HSound Level
dB (A)
Pressure
Power
82.9
– – –
79.1
– – –
79.4
– – –
♦Vibrations
Level
2
m/s
1.7
1.5
1.2

Werbung