Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions�
Panasonic Air-to-Water is a split system, consisting of two units: indoor and outdoor units� The indoor unit consist of the
•
hydromodule and 200L sanitary water tank�
•
These operating instructions describe how to operate the system using the indoor and outdoor units�
•
As for the operation of other products such as radiator, external thermo controller, and underfloor units, refer to the operating
instructions of each product�
•
System could be locked to operate in HEAT mode and disable COOL mode�
Some functions described in this manual may not be applicable to your system�
•
Must use water that complies with European water quality standard 98/83 EC� The lifespan of the Tank Unit will be shorter if
•
groundwater (include spring water and well water) is used�
The Tank Unit shall not be used with the tap water containing contaminants such as salt, acid, and other impurities which may
•
corrode the tank and its component�
Consult your nearest authorised dealer for further information�
•
*¹ The system is locked to operate without COOL mode� It can be unlocked only by authorised installers or our authorised service
partners�
*² Only displayed when COOL mode is unlocked (This means when COOL mode is available)
System overview
Remote Controller
Note:
Not recommended to open the Front Plate�
(For authorised dealer/specialist use only)
The illustrations in this manual are for explanation purposes only and may differ from the actual unit�
They are subject to change without notice for future improvement�
Operating conditions
Water outlet temperature (°C)
(Min� / Max�)
Outdoor ambient temperature (°C)
(Min� / Max�)
When the outdoor temperature is out of the range in the table, the heating capacity will drop significantly and the outdoor unit may
stop operating for its protection�
The unit will restart automatically after the outdoor temperature returns to the specified range.
* Above 55 °C, only possible with backup heater operation�
*
Between outdoor ambient -10 °C and -15 °C, the water outlet temperature gradually decreases from 60 °C to 55 °C�
3
Solar Panel
Indoor Unit
Front Plate
Outdoor Unit
WH-UD series
HEATING
HEATING
(TANK)
(CIRCUIT)
- / 65*
20 / 55
-20 / 35
WH-UX series, WH-UQ series
HEATING
HEATING
(TANK)
(CIRCUIT)
20 / 55 (Below Ambient -15 °C) *
- / 65*
20 / 60 (Above Ambient -10 °C) *
-28 / 35
EN
Radiator
Shower
Fan Coil
Unit
Floor
Heating
Power Supply
*
COOLING
1
(CIRCUIT)
3
5 / 20
3
16 / 43
3