Herunterladen Inhalt Inhalt Diese Seite drucken

Use Instructions; Maintenance - MO-EL 793 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für 793:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
Ceiling mounting with chains (not provided)
• Fasten the chains (having an appropriate length) to the ceiling, and hook them to the heater in corrispondence of all the
four E holes by means of the "S" shaped rings enclosed inside the packaging (fig.2 ).
• Keep the indicated distances between the heater and the wall/ceiling (fig.1-2-3).
• Install the heater in such a way that the lamps stay horizontally.
• A safety distance of not less than 1 m should always be left in front of the heater.
• The appliance must not be located neither directly below, nor in front of a socket-outlet.
• Do not use the heater directly near a bathtub, a shower, a swimming pool.
• Ensure that the power cable cannot come into contact with the reflector of the appliance and does not intrude into the
area of light flux.
The appliance is intended for indoor use only.
Keep the appliance dry and protected from dust
Ensure that there is no possibility of inflammable material, combustible material or
curtains coming into contact with the Heater, or lie near the heater.
3. TECHNICAL FEATURES
The infrared Industrial Heaters range is constituted by appliances having one, two, or three modules.
Each module can have a 1500 W or a 2000 W lamp (Table 2).
Model
Power supply
Power
Lamps
Range
Weight

4. USE INSTRUCTIONS

The Industrial infrared heater was designed for zone heating on large premises. Production departments, churches, gym-
nasiums are ideally application sites. With high efficiency on heating from long distance, a compact size and a light weight
a wide range on installation can be easy made. The comfort is immediate, no preheating is necessary and this can give a
large cost saving on wide air volume or where there is discontinuous presence. The radiant heating give a pleasant comfort
and the absolute silence is assured without moving parts. Without air movements there isn't the spreading of particles
or dust.
• Switch on the heater simply by connecting to the power supply.
• Do not touch the metallic parts when the heater is working.
• Ensure that the rays of the heater are directed towards the area it is wished to heat. If necessary, change the angle of
inclination by loosening the screws of the support or the modules. All users should be made aware of all aspects of
operation and safety and these instructions should be retained for reference.
• In unoccupied premises it is recommended that the heating system is switched off by disconnecting from the electrical
supply.

5. MAINTENANCE

The IR Industrial Heaters contain no moving parts and therefore very little maintenance is required other than to ensure
that there is no excessive build-up of dust/dirt on the reflectors or emitters as this can cause overheating and premature
emitter failure. To clean the appliance, wipe off with a damp cloth. Wait until it is completely dry before connecting to the
power supply.
6. EMITTER REPLACEMENT
The emitters used in the IR heater are robust and if knocks and shock vibrations are avoided, they will last for around 3000
hours. They should be substituted even before if there are signs of aging. Due to the special sealing and anti-shock design
of the heater, the emitters are not intended to be user replaceable. Please ensure that all emitters are replaced via the
Mo-El service network.
791
792
220-240 V ~
220-240 V ~
50-60 Hz
50-60 Hz
1x2000W
2x2000W
1
2
9-12 m²
12-16 m²
2.2 kg
3.0 kg
793
794
220-240 /
380-415 V ~
220-240 V ~
50-60 Hz
50-60 Hz
3P+N
3x2000W
1x1500W
3
1
16-20 m²
7-9 m²
3.8 kg
2.2 kg
5
795
796
220-240 /
220-240 V ~
380-415 V ~
50-60 Hz
50-60 Hz
3P+N
2x1500W
3x1500W
2
3
9-12 m²
12-15 m²
3.0 kg
3.8 kg
TABLE 2