AIR FLOW
Turn the roller to control the air flow direction of the vertical louvres.
Move the air vent directly to adjust the air flow direction of the horizontal
louvres.
F
DRAINAGE
The unit is equipped with an automatic drainage function. The condensed water
will be discharged from the hole placed at the back of the indoor unit. You may
also connect a water tube (dia. 14.5 mm) to the discharge hole to channel the
water away. Make sure the water always drains away freely.
G
DISCONNECTING THE INDOOR AND OUTDOOR UNIT
(FOR QUALIFIED PERSONNEL)
If the indoor unit needs to be disconnected from the outdoor unit, to place it in a
more suitable position, follow these steps:
Disconnecting
1
2
3
4
5
4
50
Open the tube connection box (12) situated at the back of the indoor unit.
Disconnect the drain tube (C).
Disconnect the electrical cable (A).
Disconnect the refrigerant tubes (B and D) using the spanners (15) provided.
The terminals are fitted with automatic self-sealing valves to prevent the gas
from leaking. Loosen the nuts quickly, so the seal is made promptly. During
the operation take extreme care not to break the refrigerant tubes.
Cap the terminals with the caps (16) provided to protect them from dust.
Mount the outdoor unit on the bracket as described on page 5.