Anhang A
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed
installation.
Note – Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
Note – Examples include switches in the fixed installation and some equipment for industrial use with per-
manent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note – Examples
include electricity meters and primary over-current protection equipment.
Anhang B
General Specifications
Display :
Update Rate :
Polarity :
Low Battery :
Operating Temperature :
Relative Humidity :
Altitude :
Storage Temperature :
Temperature Coefficient :
Sensing :
Safety :
Transient protection :
Pollution degree :
E.M.C. :
Overload Protections :
Power Supply :
Power Consumption :
APO Timing :
APO Consumption :
Dimension :
Weight :
Jaw opening & Conductor diameter : 45mm max
Special features :
Accessories :
Optional accessories :
Electrical Specifications
20
Voltage functions: 6000 counts LCD display(s)
Power, Ohm & Hz functions: 9999 counts LCD display(s)
ACA clamp-on function: 4000 counts LCD display(s)
Power function: 1 per second nominal Voltage, ACA clamp-on, Ohm, Hz &
Temperature functions: 4 per second nominal
Automatic
Below approx. 2.4V
o
o
0
C to 40
C
Maximum relative humidity 80% for temperature up to 31
arly to 50% relative humidity at 40
Operating below 2000m
o
o
-20
C to 60
C, < 80% R.H. (with battery removed)
nominal 0.15 x (specified accuracy)/
erwise specified
True RMS sensing for all models
Meets IEC61010-2-032 (1994), EN61010-2-032(1995), UL3111-2-032(1999).
Measurement Category : III 600 Volts ac & dc
6.5kV (1.2/50µs surge) for all models
2
Meets EN61326(1997, 1998/A1), EN61000-4-2(1995), and EN61000-4-
3(1996)
In an RF field of 3V/m:Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
ACA Clamp-on jaws : AC 1000A rms continuous + & COM terminals (all func-
tions) : 600VDC/VAC rms
standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2
Voltage, ACA, Hz & Power functions: 10mA typical
Ohm & Temperature functions: 4mA typical
Idle for 17 minutes
10µA typical
L224mm X W78mm X H40mm
224 gm approx
Backlight display (model 152 & 155 only); AutoVA
DCV or ACA functions); Power measurement of selectable W, VAR & VA with
dual-display Total Power Factor features; Total harmonic distortion THD%-F
(model 155 only); PEAK-rms HOLD
Test leads (pair), batteries installed, user's manual, soft carrying pouch, &
BKP60 banana plug type-K thermocouple (model 152 & 155 only)
BR15X PC interface kit (including BA-1XX optical adapter back, BC-100R
cable & Bs15x software CD), BKB32 banana plug to type-K socket plug adap-
tor (model 152 & 155 only)
o
o
C
o
o
o
C @(0
C -18
C or 28
TM
(Auto Selection on ACV,
C decreasing line-
o
o
C -40
C), or oth-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis