Warnings
For this test you have to wear goggles.
During this test keep your face away from the safety valve
because air with high pressure will escape from this valve.
Should the safety valve not function properly as described
above, switch the compressor off immediately and have
the valve checked by your retailer.
If the safety valve does not function correctly as described
above, do not work with the compressor.
General inspection
1 At regular intervals, check that all attachment screws
are properly and securely tightened.
2 Check the electric cable for damages regularly and at
frequent intervals. A damaged cable must be replaced
by an expert in order to avoid any hazard.
Cleaning
1.
Always keep the air inlets and outlets free and clean.
2.
Remove dust and dirt regularly using a soft brush or
cloth.
3.
Lubricate all moving parts at regular intervals.
4.
If the compressor body needs cleaning, wipe it with
a soft, moist cloth. You may use a mild detergent but
no alcohol, benzine or any other cleaning agent.
5.
Never use caustic agents to clean plastic parts.
Caution: The device must never get in contact with water.
m Electric connection
The electrical motor installed is connected and ready for
operation. The connection complies with the applicable
VDE and DIN provisions.
The customer's mains connection as well as the extension
cable used must also comply with these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are passed
through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be
used and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regu-
larly. Make sure that the connection cable does not
hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.