NOTE:
• The depth gauge cannot be used at the position where
the depth gauge strikes against the gear housing.
Dust cup (Fig. 17)
Use the dust cup to prevent dust from falling over the tool
and on yourself when performing overhead drilling
operations. Attach the dust cup to the bit as shown in the
figure. The size of bits which the dust cup can be attached
to is as follows.
Dust cup 5
Dust cup 9

OPERATION

Hammer drilling operation (Fig. 18)
Set the action mode changing knob to the
Position the bit at the desired location for the hole, then
pull the switch trigger.
Do not force the tool. Light pressure gives best results.
Keep the tool in position and prevent it from slipping away
from the hole.
Do not apply more pressure when the hole becomes
clogged with chips or particles. Instead, run the tool at an
idle, then remove the bit partially from the hole. By
repeating this several times, the hole will be cleaned out
and normal drilling may be resumed.
CAUTION:
• There is a tremendous and sudden twisting force
exerted on the tool/bit at the time of hole break-
through, when the hole becomes clogged with chips
and particles, or when striking reinforcing rods
embedded in the concrete. Always use the side grip
(auxiliary handle) and firmly hold the tool by both side
grip and switch handle during operations. Failure to do
so may result in the loss of control of the tool and
potentially severe injury.
NOTE:
Eccentricity in the bit rotation may occur while operating
the tool with no load. The tool automatically centers itself
during operation. This does not affect the drilling
precision.
Blow-out bulb (optional accessory)
(Fig. 19)
After drilling the hole, use the blow-out bulb to clean the
dust out of the hole.
Chipping/Scaling/Demolition (Fig. 20)
Set the action mode changing knob to the
Hold the tool firmly with both hands. Turn the tool on and
apply slight pressure on the tool so that the tool will not
bounce around, uncontrolled. Pressing very hard on the
tool will not increase the efficiency.
Drilling in wood or metal (Fig. 21 & 22)
For Model BHR261 only
Use the optional drill chuck assembly. When installing it,
refer to "Installing or removing the bit" described on the
previous page.
Bit diameter
6 mm - 14.5 mm
12 mm - 16 mm
symbol.
symbol.
Set the action mode changing knob so that the pointer
points to the
symbol.
For Model BHR261T only (Fig. 23, 24 & 25)
Use the quick change drill chuck as standard equipment.
When installing it, refer to "changing the quick change
chuck for SDS-plus" described on the previous page.
Hold the ring and turn the sleeve counterclockwise to
open the chuck jaws. Place the bit in the chuck as far as it
will go. Hold the ring firmly and turn the sleeve clockwise
to tighten the chuck. To remove the bit, hold the ring and
turn the sleeve counterclockwise.
Set the action mode changing knob to the
You can drill up to 13 mm diameter in metal and up to
32 mm diameter in wood.
CAUTION:
• Never use "rotation with hammering" when the drill
chuck assembly is installed on the tool. The drill chuck
assembly may be damaged. Also, the drill chuck will
come off when reversing the tool.
• Pressing excessively on the tool will not speed up the
drilling. In fact, this excessive pressure will only serve
to damage the tip of your bit, decrease the tool
performance and shorten the service life of the tool.
• There is a tremendous twisting force exerted on the
tool/bit at the time of hole breakthrough. Hold the tool
firmly and exert care when the bit begins to break
through the workpiece.
• A stuck bit can be removed simply by setting the
reversing switch to reverse rotation in order to back
out. However, the tool may back out abruptly if you do
not hold it firmly.
• Always secure small workpieces in a vise or similar
hold-down device.

MAINTENANCE

CAUTION:
• Always be sure that the tool is switched off and the
battery cartridge is removed before attempting to
perform inspection or maintenance.
Replacing carbon brushes (Fig. 26)
Remove and check the carbon brushes regularly. Replace
when they wear down to the limit mark. Keep the carbon
brushes clean and free to slip in the holders. Both carbon
brushes should be replaced at the same time. Use only
identical carbon brushes.
Use a screwdriver to remove the brush holder caps. Take
out the worn carbon brushes, insert the new ones and
secure the brush holder caps. (Fig. 27)
Remount the holder cap covers on the tool.
To maintain product SAFETY and RELIABILITY, repairs,
any other maintenance or adjustment should be
performed by Makita Authorized Service Centers, always
using Makita replacement parts.
ACCESSORIES
CAUTION:
• These accessories or attachments are recommended
for use with your Makita tool specified in this manual.
The use of any other accessories or attachments might
present a risk of injury to persons. Only use accessory
or attachment for its stated purpose.