CF
CF13
Configuration
CF14
Parameters
CF15
CF16
CF19
CF20
CF22
CF23
CF24
CF25
CF26
CF27
CF28
CF29
CF30
CF32
CF33
CF34
CF35
CF36
CF37
CF38
CO01
CO02
CO
CO05
Refrigerant
CO12
compressor
parameters
CO14
FA
N.U.
AL01
AL02
AL03
AL08
Cod. 710.0145.40.00 Rev0C – 05.2009
ID2-MF digital input polarity (REMOTE ON/OFF)
0 = active with close contact
1 = active with open contact
ID3 digital input polarity (1P1)
0 = active with close contact
1 = active with open contact
ID4 digital input polarity
0 = active with close contact
1 = active with open contact
ID5 digital input polarity (1Q2 – FAN THERMAL PROTECTION)
0 = active with close contact
1 = active with open contact
PB4 polarity (REFRIGERANT CIRCUIT SUCTION)
0 = active with close contact
1 = active with open contact
Condensate drain valve/s relais polarity(RL4)
0 = active with close contact
1 = active with open contact
Refrigerant pressure value = 4ma
Refrigerant pressure value = 20ma
PB1 probe calibration offset (DEW POINT)
PB2 probe calibration offset (AIR INLET)
PB3 probe calibration offset (AMBIENT)
PB4 probe calibration offset (REFRIGERANT CIRCUIT SUCTION)
Condensate drain unit operation
0 = Always ON
1 = Timed
Condensate drain ON - time
Condensate drain OFF - time
Selection: ° C or ° F
0 = ° C / BAR
1 = ° F / psi
Selection of mains frequency
0 = 50 Hz
1 = 60 Hz
2 = Direct current
Serial address
Remote controller
0 = 4 buttons
1 = 6 buttons
2 = 6 buttons with NTC probe on board
Default controller display
0 = IN / PROBE
1 = OUT / PROBE
2 = IN / rtC
3 = OUT / rtc
Firmware release
EEprom parameters map
Pr2
Password
Minimum delay at compressor re-start
Minimum delay for compressor stop
Delay at Refrigerant Compressor start form Power ON
Refrigerant Compressor 1
0 = ON
1 = OFF
Refrigerant Compressor hour counter SET (SUGGESTED
MAINTENANCE)
Pr2
Password
---
---
Digital input low pressure alarm delay
Low pressure digital input Max. number of activations / hour
Low pressure alarm with dryer in remote OFF status or stand-by
0 = alarm detection OFF
1 = alarm detection ON
Refrigerant compressor thermal protection alarm delay at start
1
1
0
1
1
0
0
bar
30
bar
-1
° C/° F
0
° C/° F
0
° C/° F
0
° C/° F
1
3
Sec
60
Sec
0
2
1
1
0
2.0
1
18
sec 10x
18
sec10x
48
min10x
0
0
h 10x
5
Sec
5
1
1
Sec
17 - 275