plug during installation. Connections made
by cutting off render the product warranty
void and pose a danger to user safety.
1- Installation with flue - the
aspirated air is transferred to
the outdoor through a flue;
Installation dimensions and details
(Figure 3a-3b-4a-4b)
• The dimensions for the installation with
double flue are shown in Figure 3b.
• If the installation will be carried out as
a double-chimney, the length from the
required clearance distance above the hob
to your furniture shall be in the range of
910-1138 mm. (Figure 4b)
• If the installation will be carried out as a
single chimney, the length from the required
clearance distance above the hob to your
furniture shall be 748 mm. (Figure 3a-4a)
For a single flue installation, use the upper
flue with a ventilation hole.
Installation of product fixing parts
(Figure 5-6-7a-7b)
• Centre your hob and draw a vertical axis
line on the wall.
• Draw a horizontal reference line by
measuring a 650 mm distance from the
upper point of your hob. (Figure 5)
• Centre the supplied template to the
reference point drawn and stick it on the
wall and mark the holes in the template
with a pencil. (Figure 6)
• From the top of your furniture or ceiling,
mark the holes for the flue fixing parts as
per the dimensions shown in figure 6.
• Fix the hood fixing part and flue fixing parts
to the wall as indicated in figures 7a and
7b. Single-flue use is shown in figure 7a,
and double-flue use in figure 7b. (Part A is
intended for the installation with a carbon
filter)
Hanging, aligning and fixing the hood
(Figures 8-9-10-11)
• Hang your hood on the hood fixing part
that you have fixed to the wall. (Figure 8)
• Align your hob in a central position by
sliding the hood to the right and the left
direction on the fixing part. (Figure 9)
• Remove the aluminium (oil) filters as shown
in figure 10.
• Secure your hood to the hood fixing part
and to the wall as shown in figure 11.
• Reinstall the aluminium (oil) filters.
Installing flue outlet pipes (Figure
12a)
• Mount the cover preventing the reverse air
flow at the flue outlet as shown in Figure
12a.
• If the diameter of your flue outlet pipe is
150 mm, mount the flue outlet pipe on the
cover.
• If the diameter of your flue outlet pipe is
120 mm, mount the flue outlet pipe after
placing the flue connection adapter on the
cover.
• Insulate the joints appropriately.
Securing the flue extensions (Figure
13-14)
• Adhere the tape supplied with the
product around the joint of the plastic part
preventing reverse air flow and the hood
flue outlet (Figure 13).
• If you perform the installation with one-
piece extension, secure the flue extension
with screw hole with 2 screws through the
lower holes on the hood as shown on the
left in figure 14. Complete the installation
by securing it with 2 screws from inside the
hood as shown below in Figure 14.
• If you perform the installation with two-
piece extension, first fix the upper flue
extension with 4 screws as shown on
the right in figure 14. Then, complete the
installation by placing the lower extension
into the upper extension and securing it
with 2 screws from inside the hood as
shown below in Figure 14.
2- Installation with a carbon
filter where aspirated air will
be transferred to the indoor
by passing through a carbon
filter
• In the carbon filter installation, the air
sucked from the environment passes
through the aluminium filter and is purified
from odours. After passing through the
carbon filters and the air diverter, it is
supplied back to the environment through
the ventilation grilles on the side surface of
the flue. Flue outlet pipes are not used in
carbon filter installation.