INSPECTING CLEANING CAPACITY AND
FUNCTIONS OF THE PLANT
The plant's cleaning capacity must be inspected according to the following periods
unless the water treatment is used commercially:
Turn the plant off for changing the emitter to avoid accidentally turning
on the UVC light. Do not look into the functioning emitter and never
remove the protective cap if the plant is turned on. The UVC light is
hazardous, especially for the eyes.
42
• Daily check of the plant for leakage, specifically the inlet side close to the valve
• Every 10 days the plant needs to be used or cleaned by manually starting the
rinse cycle. The plant's parts need to be checked for leakage too.
• Monthly inspection of the pre filters (more often in case of heavily polluted water
or excessive use)
• Annual inspection of all parts and hose connections for leakage and cleaning of
the UVC reactor. Also make sure that all connections are firmly secured.
• Annual change of the diaphragm, more often in case of congestions or reduced
production capacity.
• Changing the UVC emitter in case of dark spots or after 10 years – carefully pull
out the cable connection and remove the emitter. Connect the plug and the new
emitter before removing the protective tube made of cardboard, do not hold the
new emitter with bare hands. Insert the emitter immediately after that.