SHUT DOWN

If you plan a long absence from the boat, someone
needs to flush the plant every 10 days (the plant and
the pressure pump of the ship's water supply must be
activated for this). Alternatively, you can preserve the
diaphragm by filling in a preserving agent. Disconnect
the intake hose from the closed seacock and dip it into
a bucket filled with a preserving solution. The overflow
must be channeled to the bucket as well. Start the plant
and let it run for 15 minutes, after which the plant must
be stopped by cutting the power supply(do not use the
STOP function or else the rinse cycle starts!). You can
simply disconnect the fuse or toggle the on board main
switch to achieve this. Now the plant is conserved for
one year at most.
FULLY AUTOMATED WATER TREATMENT PLANT FOR YACHTS AND HOUSEBOATS

WINTERISING THE PLANT

If the plant is not in use, it needs to be winterised in all
regions with risk of frost. Use the same antifreeze as
for the fresh water plant. Drain the plant and turn on
the pump to flush all hoses with antifreeze. The filter
and UVC casings need to be drained as well to avoid
ice. Remove the emitter and unscrew the UVC casing to
extract the glass tube.
Afterwards, the hoses need to be drained as
much as possible. The procedure is similar to
the preserving procedure.
AN OPERATING PLANT MUST BE FROST-
PROOF AND OPERATED AT 5°C MINIMUM.