Regulations

2.5

Product datasheet on energy consumption

The following product data complies with the requirements of EU Regulations 811/2013 and 812/2013 as supplement to the Directive 2010/30/EU.
Product number
Product typ
7 735 500 675
SM290.5 E
8 718 541 200
SM290/5E
8 718 541 295
SM290/5 EW
7 735 500 677
SM300.5
8 718 541 306
SM300/5
8 718 541 311
SM300/5 W
7 735 500 678
SM400.5 E
8 718 541 060
SM400/5E
8 718 541 319
SM400/5 EW
Table 5 Product datasheet on energy consumption
2.6

Product description

3
Regulations
Observe the following directives and standards:
• Local regulations
• EnEG (in Germany)
• EnEV (in Germany)
Installation of, and equipment for, heating and water heating systems:
• DIN and EN standards
– DIN 4753-1 – Water heaters ...; requirements, identification,
equipment and testing
– DIN 4753-3 – Water heaters ...; corrosion protection on the
water side through enamel coating; requirements and testing
(product standard)
– DIN 4753-6 – Water heating systems ...; cathodic corrosion
protection for enamelled steel cylinders; requirements and
testing (product standard)
– DIN 4753-8 – Water heaters ... , part 8: Thermal insulation of
DHW cylinders up to 1000 l nominal capacity – requirements and
testing (product standard)
– DIN EN 12897 – Water supply - regulation for ... DHW cylinders
(product standard)
40
Storage volume (V)
Standing loss (S)
290,0 l
93,0 W
290,0 l
80,0 W
371,1 l
100,0 W
• DVGW
4
▶ When handling, prevent DHW cylinders from falling.
▶ Move packed DHW cylinder with a sack trolley and strap ( Fig. 5,
-or-
▶ Move unpacked DHW cylinder with a transport net; during handling,
5
The DHW cylinder is delivered as a fully assembled unit.
▶ Check that the DHW cylinder is complete and undamaged.
5.1
5.1.1
▶ Site the DHW cylinder on a plinth if there is a risk that water may
▶ Site the DHW cylinder in dry internal areas that are free from the risk
▶ Observe the minimum room height ( Table 4, page 39) and
5.1.2
▶ Stand the DHW cylinder upright and level it ( Fig. 6 to Fig. 9,
▶ Remove protective caps.
▶ Apply Teflon tape or Teflon string ( Fig. 10, page 66).
Water heating energy efficiency class
– DIN 1988 – Technical rules for potable water installations
– DIN EN 1717 – Protection of potable water against
contamination ...
– DIN EN 806 – Technical rules for potable water installations
– DIN 4708 – Central DHW heating systems
– EN 12975 – Solar thermal systems and their components
(collectors).
– Code of practice W 551 – Potable water heating systems and
pipework; technical measures to inhibit the growth of legionella
bacteria in new systems; ...
– Code of Practice W 553 – Sizing DHW circulation systems ... .

Transport

page 65).
protect connections against possible damage.

Installation

Siting

Installation site requirements

collect at the installation site.
of frost.
minimum wall clearances inside the installation room
( Fig. 6, page 65).

Positioning the DHW cylinder

page 66).
SM290.5 E | SM300.5 | SM400.5 E – 6 720 819 314 (2017/07)
C
C
C