Herunterladen Diese Seite drucken

Product Information; Correct Use; Scope Of Delivery; Technical Data - Buderus P120.5 Installations- Und Wartungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
2

Product information

2.1

Correct use

Buffer cylinders may only be filled with heating water.
Only use buffer cylinders in sealed heating systems.
Operate the buffer cylinders P120.5, P200.5, P300.5 preferably in
combination with heat pumps.
Any other use is considered incorrect. Any damage that may result is
excluded from liability.
2.2

Scope of Delivery

• Buffer cylinder
• Installation and servicing instructions
2.3

Technical data

• Dimensions and specifications ( Fig. 1, page 42)
Available capacity (total)
1)
Standby heat loss
Maximum heating water
temperature
Maximum heating water operating
pressure
Table 2 Technical data (A)
1) EN 12897; Excluding distribution losses outside the buffer cylinder.
Available capacity (total)
1)
Standby heat loss
Maximum heating water
temperature
Maximum heating water
operating pressure
Table 3 Technical data (B)
1) EN 12897; Excluding distribution losses outside the buffer cylinder.
2.6

Product datasheet on energy consumption

The following product data complies with the requirements of EU Regulations 811/2013 and 812/2013 as supplement to the Directive 2010/30/EU.
Product number
Product typ
8 732 910 192
P120.5 S
7 735 500 667
P120.5
8 718 542 920
P120/5W
8 732 910 194
P200.5 S
7 735 500 668
P200.5
8 718 543 041
P200/5W
7 735 500 684
P300.5
8 718 542 847
P300/5W
Table 6 Product datasheet on energy consumption
P120.5 | P200.5 | P300.5 – 6 720 819 267 (2018/08)
P120.5
P200.5
Unit
A
l
120
203
kWh/24h
0,8
1,03
°C
90
bar
3
(positive)
P120.5
P200.5
P300.5
Unit
B
B
l
120
203
300
kWh/24h
1,3
1,4
1,94
°C
90
90
bar
3
3
(positive)
Storage volume (V)
120,0 l
120,0 l
203,0 l
203,0 l
300,0 l
2.4

Product description

Item
Description
1
Heating system flow
2
Casing, painted sheet metal with rigid polyurethane foam
insulation
3
Heating system return
4
Return to heat pump
5
Sensor well for return temperature sensor (GT1)
(Test point)
6
Drain tap
7
Storage cylinder, steel
8
Flow from heat pump
9
Plug with sensor well for flow temperature sensor (T1)
10
Air vent valve
11
PS casing lid
A
Table 4 Product description ( Fig. 2, page 43)
2.5

Data plate

90
The data plate is located at the top of the rear of the buffer cylinder and
includes the following details:
3
Item
Description
1
Type
2
Serial number
3
Available capacity (total)
4
Standby heat loss
6
Year of manufacture
B
9
Max. heating water flow temperature
17
Max. heating water operating pressure
Table 5 Data plate
90
3
Standing loss (S)
35,2 W
52,0 W
42,7 W
56,6 W
59,0 W
Product information
Water heating energy efficiency class
A
B
A
B
B
2