Herunterladen Inhalt Inhalt Diese Seite drucken

Specification; Product Datasheet On Energy Consumption - Buderus SU300.5 serie Installations- Und Wartungsanleitung Für Den Fachhandwerker

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
2
Product information
2.4

Specification

General data
Dimensions
Height when tilted
Minimum room height for anode replacement
Connections
Connection size, DHW
Connection size, cold water
Connection size, DHW circulation
Internal diameter, test port, cylinder temperature sensor
Weight (dry, excl. packaging)
Total weight when filled
Cylinder capacity
Available capacity (total)
1)
Available amount of DHW
DHW outlet temperature
45 °C
40 °C
Standby heat loss to DIN 4753 part 8
Maximum throughput, cold water inlet
Maximum DHW temperature
Max. operating pressure, DHW
Highest design pressure (cold water)
Maximum DHW test pressure
Indirect coil
Contents
Surface area
Performance factor N
to DIN 4708
L
Continuous output (at 80 °C flow temperature, 45 °C DHW outlet temperature and 10 °C cold water
temperature)
Heat-up time at rated output
5)
Maximum heat input
Maximum heating water temperature
Max. heating water operating pressure
Connection size, heating water
Pressure loss diagram
Table 4 Dimensions and specification (
1) Without solar heating or reheating; selected cylinder temperature 60 °C
2) Mixed water at the draw-off point (at 10 °C cold water temperature)
3) Distribution losses outside the buffer cylinder are not taken into account.
4) The performance factor NL=1 to DIN 4708 for 3.5 occupants, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10 °C. Measured
at max. heat input. The N
drops with reduced heat input.
L
5) Limit to the stated value for heat sources with higher heat input.
2.5

Product datasheet on energy consumption

The following product data complies with the requirements of EU Regulations 811/2013 and 812/2013 supplementing EU Directive 2017/1369.
Implementation of these directives, with the ErP values indicated, allows manufacturers to use the "CE" mark.
Product number
Product typ
7 735 500 680
SU300.5
8 718 541 326
SU300/5
8 718 541 331
SU300/5 W
7 735 500 681
SU400.5
8 718 541 335
SU400/5
8 718 541 338
SU400/5 W
Table 5 Product datasheet on energy consumption
36
2)
:
3)
4)
Fig. 1, page 52 and Fig. 3, page 53)
Storage volume (V)
294,0 l
380,9 l
bar (positive)
bar (positive)
bar (positive)
bar (positive)
Standing loss (S)
Water heating energy efficiency class
78,8 W
88,3 W
Unit
SU300.5
 Fig. 1, page 52
mm
1655
mm
1850
 Table 6, page 37
DN
R1"
DN
R1"
DN
R¾ "
mm
19
kg
105
kg
405
l
294
l
420
l
490
kWh/24h
1,9
l/min
30
°C
95
10
7,8
10
l
8,8
2
m
1,3
NL
7,8
kW
36,5
l/min
15
min
39
kW
36,5
°C
160
16
DN
R1"
 Fig. 2, page 53
C
C
SU300.5 | SU400.5 – 6 720 819 326 (2019/12)
SU400.5
1965
2100
R1"
R1"
R¾ "
19
119
509
381
544
635
2,12
39
95
10
7,8
10
12,1
1,8
12,5
56
23
41
56
160
16
R1"

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Su400.5 serieSu300.5Su300/5 wSu400.5Su400/5 w

Inhaltsverzeichnis